User Tools

Site Tools


feed_status

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
feed_status [2018/05/25 23:32] – [May 25, 2018] jrsetifeed_status [2023/10/28 18:36] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ===== Feed Status===== ===== Feed Status=====
  
-This is a general feed status report. The status reports will be in reverse chronological order.+The 16 new feeds are: **1c,1e,1g,1h,1k,2a,2b,2e,2h,2j,2m,3c,3d,3l,4j,5b**
  
-The 16 new feeds are: 1c,1e,1g,1h,1k,2a,2b,2e,2h,2j,2m,3c,3d,3l,4j,5b+  * A description of how the feeds are tested each week, see [[feed_testing|Feed Testing]] 
 +  * [[http://setiquest.info/docs/feed-control-commands.pdf|Feed control commands document]]  
 +  * [[http://setiquest.info/data/antfeeds_measurements-87aa42.zip|Feed control measurements during commissioning]]  
 +  * [[turbo_pump_procedure|Notes on resetting a turbo pump on 2j]]
  
-====May 25, 2018====+====Feed Sensors====
  
-The storm last week took its toll on 5 of the new feeds. Report from Elin:+The sensors on the dishes and on the feeds are now periodically samples. The values are stored in a MySQL database. There is a duplicate.
  
-  ant1k  - 2018-05-18 13:00:00  will not cool past 125Have shutoff per minex recommendation +  * Stored locally on sonata@10.1.49.80 (the server called sonata1") 
-  ant2a  - 2018-05-18 13:00:00  after power outage not cooling 48 volt doesnt seem to turn anything on. +  * **USING MYSQL WORKBENCHStored on a Google Cloud VM instanceThe server is user "db"address "35.233.233.72". This instance is available for anyone to perform SELECT commands only. I suggest using MySQL Workbench, available free at https://dev.mysql.com/downloads/file/?id=474219 to view the data.**
-  ant2h -  2018-05-18 13:00:00  will not cool past 90. Have shutoff per minex recommendation +
-  ant3l -  2018-05-18 13:00:00  noisy before but coolingnow after power outage not cooling 48 volt doesnt seem ... +
-  ant4j -  2018-05-18 13:00:00  will not cool past 125Have shutoff per minex recommendation+
  
-So, the list of useable antennal pols is getting smaller. I . don't know if I believe the results of bestabtpols.+There are 2 tables:
  
-**bestantpols result from 2018-05-24**+  various_sensors - this table contains sensor values from various locations on the dishes. Including the cryotemp. This data is sampled every 5 minutes going back to September 2014. 
 +  feed_sensors - this table contains sensor reading from the feed control board and vacuum control board. Basically anything mentioned in http://setiquest.info/docs/feed-control-commands.pdf . Sample rate is every 4 hours. Note: March 17, 2019 the rate was changed to 30 minutes.
  
-**1430:** +The code and usage documentation is at https://github.com/SETIatHCRO/ATA-Utils/tree/master/FeedSensors
-  Ants: 2j,2b,1h,1f,1a,2d,4l,2f,5e,1b +
-  Antpols: 2jy,2by,1hx,2bx,1fx,1ax,1ay,2dy,4ly,2fy,1fy,5ey,5ex,1bx +
-   +
-**3040** +
-  Ants: 2j,1h,2b,1f,1a,2d,2f +
-  Antpols: 2jy,1hx,2bx,2by,1fx,1fy,1ay,2dy,1ax,2fy+
  
-**4500** +====Where does it run?==== 
-  Ants2j,1f,1a,2d + 
-  Antpols2jy,1fy,1ay,1ax,1fx,2dy+obs@tumulus:~ 20:01:43 > ssh ataant@antcntl 
 +ataant@antcntl:~/jrichards
  
-**6667** 
-  Ants: 1a,1f,2j,2d,2f 
-  Antpols: 1ay,1fy,1fx,1ax,2jy,2dy,2fy 
-   
-**8400** 
-  Ants: 2b,1h,2f,2j 
-  Antpols: 2by,1hx,2bx,2fy,2jy 
  
feed_status.1527291140.txt.gz · Last modified: 2023/10/28 18:36 (external edit)

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki