feed_status [2018/05/25 23:20] jrsetifeed_status [2023/10/28 18:36] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ===== Feed Status===== ===== Feed Status=====
  
-This is a general feed status report. The status reports will be in reverse chronological order.+The 16 new feeds are: **1c,1e,1g,1h,1k,2a,2b,2e,2h,2j,2m,3c,3d,3l,4j,5b**
  
-The 16 new feeds are: 1c,1e,1g,1h,1k,2a,2b,2e,2h,2j,2m,3c,3d,3l,4j,5b+  * A description of how the feeds are tested each week, see [[feed_testing|Feed Testing]] 
 +  * [[http://setiquest.info/docs/feed-control-commands.pdf|Feed control commands document]]  
 +  * [[http://setiquest.info/data/antfeeds_measurements-87aa42.zip|Feed control measurements during commissioning]]  
 +  * [[turbo_pump_procedure|Notes on resetting a turbo pump on 2j]]
  
-====May 25, 2018====+====Feed Sensors====
  
-The storm last week took its toll on 5 of the new feeds. Rport from Elin:+The sensors on the dishes and on the feeds are now periodically samples. The values are stored in a MySQL database. There is a duplicate.
  
-  ant1k  - 2018-05-18 13:00:00  will not cool past 125Have shutoff per minex recommendation +  * Stored locally on sonata@10.1.49.80 (the server called sonata1") 
-  ant2a  - 2018-05-18 13:00:00  after power outage not cooling 48 volt doesnt seem to turn anything on+  * **USING MYSQL WORKBENCHStored on a Google Cloud VM instance. The server is user "db", address "35.233.233.72". This instance is available for anyone to perform SELECT commands only. I suggest using MySQL Workbench, available free at https://dev.mysql.com/downloads/file/?id=474219 to view the data.** 
-  ant2h -  2018-05-18 13:00:00  will not cool past 90. Have shutoff per minex recommendation + 
-  ant3l  2018-05-18 13:00:00  noisy before but cooling, now after power outage not cooling 48 volt doesnt seem ... +There are 2 tables: 
-  ant4j  2018-05-18 13:00:00  will not cool past 125Have shutoff per minex recommendation+ 
 +  * various_sensors this table contains sensor values from various locations on the dishesIncluding the cryotempThis data is sampled every 5 minutes going back to September 2014
 +  * feed_sensors this table contains sensor reading from the feed control board and vacuum control board. Basically anything mentioned in http://setiquest.info/docs/feed-control-commands.pdf . Sample rate is every 4 hours. NoteMarch 17, 2019 the rate was changed to 30 minutes. 
 + 
 +The code and usage documentation is at https://github.com/SETIatHCRO/ATA-Utils/tree/master/FeedSensors 
 + 
 +====Where does it run?==== 
 + 
 +obs@tumulus:~ 20:01:43 > ssh ataant@antcntl 
 +ataant@antcntl:~/jrichards
  
  
feed_status.1527290439.txt.gz · Last modified: 2023/10/28 18:36 (external edit)